http://bugs.winehq.org/show_bug.cgi?id=14717 --- Comment #229 from Raymond <superquad.vortex2(a)gmail.com> 2011-11-11 01:01:51 CST --- (In reply to comment #227)
HDA codecs typically use 96000Hz or 192000Hz as their base internal samplerate (ones that don't use PDM internally,
Take a look at HDA specification, 5.4.2 Link Sample Delivery Timing 48-kHz Delivery Timings This becomes straight forward for streams whose sample rate is a natural harmonic of 48 kHz. In this case the base rate multiple also defines the number of complete sample blocks that must be transmitted in each frame. For either input or output, there must be transmitted on the link “y” complete sample blocks (block includes one sample for each channel in the stream) on every nth frame as shown in Table 57. For example, with a multiple of 4 (192 kHz sample rate), there must be four sample blocks transmitted in every frame on the link; -- Configure bugmail: http://bugs.winehq.org/userprefs.cgi?tab=email Do not reply to this email, post in Bugzilla using the above URL to reply. ------- You are receiving this mail because: ------- You are watching all bug changes.